Influence of transducer's type in bilateral conductive and mixed hearing loss masking
Influência do tipo de transdutor no mascaramento em deficiência auditiva condutiva e mista bilateral
Lívia Tamie Oshiro; Marcela Rosana Maia da Silveira; Daniela Gil
Abstract
Purpose: this study aimed at examining the influence of transducer´s type in the amount of masking needed to obtain air and bone conducted thresholds in subjects with conductive and mixed hearing losses.
Method: 16 patients with symmetric bilateral conductive hearing deficiency or mixed hearing loss with air-bone gap of at least 15dBNA were examined. The subjects underwent clinical history, otoscopy and acoustic immittance measures (tympanometry and acoustic reflex), and subsequently, pure tone and speech audiometry (SRT and WRS). Pure tone threshold and speech audiometry were performed both with supra-aural TDH-39 and insertion earphones ER-3A.
Results: there was no statistically significant difference between the ears regardless of the type of transducer. The amount of masking used with the insertion earphone ER-3A in order to test the air thresholds, in the frequencies of 250Hz and 500Hz, was lower than the one used with supra-aural headset with statistical significance.
Conclusions: transducer´s type influences in the amount of masking used in order to obtain air and bone conducted thresholds, mainly in the low frequencies, whereas the amount of masking with the insertion phone is smaller, both for testing the air as well as the bone thresholds.
Keywords
Resumo
Objetivo: verificar a influência do tipo de transdutor na quantidade de mascaramento necessária para obtenção de limiares por vias aérea e óssea em indivíduos com deficiência auditiva condutiva e mista.
Método: foram avaliados 16 indivíduos com presença de deficiência auditiva condutiva ou mista bilateral simétrica com gap aéreo-ósseo de no mínimo 15dBNA. Os indivíduos foram submetidos à anamnese, meatoscopia, medidas de imitância acústica, audiometria tonal liminar e audiometria vocal, realizadas com fones supra-aurais TDH-39 e com os fones de inserção ER-3A.
Resultados: não houve diferença estatisticamente significante entre as orelhas independentemente do tipo de transdutor. A quantidade de mascaramento utilizada com o fone de inserção ER-3A para testar a via aérea, nas frequências de 250Hz e 500Hz, foi menor do que a utilizada com o fone supra-aural, com significância estatística.
Conclusões: há influência do tipo de transdutor na quantidade de mascaramento utilizada para obtenção dos limiares de via aérea e via óssea, principalmente nas frequências baixas, sendo que a quantidade de mascaramento com o fone de inserção é menor tanto para testar a via aérea como a via óssea.
Palavras-chave
Referencias
1. Gil D, Borges ACC. Fones de Inserção: Um estudo em indivíduos audiologicamente normais. Revista Brasileira Otorrinolaringologia. 2001;67(4):480-7.
2. Clemis JD, Ballad WJ, Killion MC. Clinical use of an insert earphone. The annals of Otology Rhinology and Laryngology.1986;95:520-4.
3. Lilly DJ, Purdy JK. On the routine use of tubephone insert earphones. Am. J. Audiol. 1993;2:17-20.
4. Sklare DA, Denenberg LJ. Interaural attenuation for tubephone insert earphones. Ear Hear. 1987;8(5):298-300.
5. Van Campen LE, Sammeth CA, Peek BF. Interaural attenuation using ER-3A insert earphones in auditory brain stem response testing. Ear Hear. 1990;11(1):66-9.
6. Frank T, Wright DC. Attenuation provided by four different audiometric earphone systems. Ear Hear. 1990;11(1):70-8.
7. Blackwell KL, Oyler RF, Seyfried DN. A clinical comparison of Grason Stadler insert earphones and TDH-50P standart earphones. Ear Hear.1990;12(5):361-2.
8. Mueller HG, Hall JW. Pure tone audiometry. San Diego: Singular; 1997. Diagnostic Audiology, Principles, Procedures and Practices; p. 78-112.
9. Munro KJ, Agnew N. A comparison of inter-aural attenuation with the Etymotic ER-3A insert earphone and the Telephonics TDH-39 supra-aural earphone. Br.J.Audiol. 1999;33(4):259-62.
10. Ramos JMP, Dabbur R, Gil D. Atenuação Interaural: Estudo Comparativo com dois tipos de transdutores. Rev Soc Bras de Fonoaudiol. 2009;14(3):498-502.
11. Hosford-Dunn H, Kuklinski AL, Raggio M, Haggerty HS. Solving Audiometric masking dilemmas with an insert masker. Arch.Otolaryngol. Head Neck Surg.1986;112:92-5.
12. Katz J. Mascaramento Clínico Tomando decisões. Tratado de Audiologia Clínica. São Paulo: Manole;1999.p.109-31.
13. Munhoz MS, Caovilla HH, Silva MLG, Ganança MM. Audiologia Clínica. São Paulo:Atheneu;2000. Cap. 5. Audiometria tonal e vocal; p. 49-72.
14. Santos TMM, Russo ICP. A prática da audiologia clínica. São Paulo: Cortez; 2007. Determinação dos Limiares Tonais por Via aérea e por via óssea; p.67-95.
15. Killion MC, Wilber LA, Gudmendsen MA. Insert earphone for more interaural attenuation. Hearing Instruments.1985;36(2):34-6.
16. Zwislocki J. Acoustic attenuation between the ears. J. Acoust.Soc.Am.1953;25:752-9.
17. Zwislocki J et al. Earphones in audiometry. The Journal of the Acoustical Society of America.1988; 83(4):1688-9.
Submitted date:
15/10/2010
Accepted date:
13/06/2011